iZONE Datasheets

Technical Specifications & Product Documentation

Complete engineering datasheets for all 9 iZONE hydronic fan coil unit models. Capacities, dimensions, airflow rates, noise levels, and piping details for specifying engineers and installers.

Fan Coil Unit Datasheets

Select a model below to view the full technical datasheet with performance tables, dimensional drawings, and installation specifications.

Need help selecting a unit?

Our engineering team can help you choose the right iZONE configuration for your project. From single-room retrofits to multi-zone commercial systems, we have a solution.

Contact Engineering
2-Pipe System

Cassette Fan Coil Unit

Model HLC 102UE

5.4 kW cooling capacity

8.1 kW heating capacity

Ceiling-integrated, 4-way air distribution

View Datasheet
4-Pipe System

4-Pipe Cassette Unit

Model HLC 102UE 4R

Simultaneous heating & cooling

Independent dual coil design

Ceiling cassette, 4-way distribution

View Datasheet
Wall-Mounted

Split Fan Coil Unit

Model HLC 102G

5.6 kW cooling capacity

8.22 kW heating capacity

Direct split AC replacement

View Datasheet
Concealed / Ducted

Horizontal Concealed Unit

Model HLC 102HC

Up to 50 Pa static pressure

Fully concealed above ceiling

Flexible duct run options

View Datasheet
Freestanding

Vertical Exposed Unit

Model HLC 102VE

270 mm wide tower design

Ideal for retrofit projects

Simple floor-standing install

View Datasheet
Coming Soon

Horizontal Exposed Unit

Model HLC 102HE

Exposed or semi-concealed ceiling mount

Datasheet available soon

High Capacity

Floor Standing Unit

Model HLC-20LZ 5HP

10 kW cooling capacity

15 kW heating capacity

High-capacity commercial unit

View Datasheet
Ultra Compact

Ultra Thin Unit

Model HLF 40V

Just 130 mm wide

2.8 kW cooling / 4.2 kW heating

Ultra-quiet at 36 dB(A)

View Datasheet
Coming Soon

Universal Type Unit

Model HLF 102VU

Versatile universal configuration

Datasheet available soon

Need Engineering Support?

Our technical team can help with unit selection, system design, and specification assistance for your next hydronic HVAC project.

Contact Engineering Team

Frequently Asked Questions

What is a hydronic fan coil?

A hydronic fan coil is an indoor climate-control unit that uses chilled or heated water piped from a central heat pump or chiller to condition air in individual rooms or zones. A fan draws room air across a water-filled heat exchanger coil, delivering cooled or heated air without any refrigerant inside the occupied space. This makes hydronic systems safer, quieter, and more energy-efficient than traditional split AC.

What is the difference between 2-pipe and 4-pipe systems?

A 2-pipe system uses one supply and one return pipe, providing either heating or cooling at any given time. A 4-pipe system uses two independent sets of pipes (one for chilled water, one for hot water), allowing simultaneous heating and cooling in different zones. 4-pipe systems offer greater flexibility for buildings that need heating in some areas and cooling in others at the same time.

Can iZONE work with any heat pump?

iZONE fan coil units are designed to work with any hydronic heat pump or chiller that supplies chilled and/or heated water. They pair optimally with Karnot iHEAT R290 heat pumps for a complete PFAS-free system, but are compatible with any standard hydronic water loop operating within the specified temperature and flow rate ranges listed in each datasheet.